Pet Reptile Trichomonas Antigen Test

SKU : VD100Q

จำนวน

แบรนด์: Vetdiagnostix
รายละเอียดสินค้า

Description
The Pet Reptile Trichomonas Ag Test is a lateral flow immunochromatographic assay designed for detection of Tetratrichomonas gallinarum antigen (PR. TGA Ag) in reptile cloaca secretions or feces. It offers two options for result reading: visual judgment or semi-quantitative analysis with the FIC-Q100N Dry Immunoassay Analyzer (required only for Method 2).

Specification
Intended Use:detection of Tetratrichomonas gallinarum antigen
Principle: lateral flow immunochromatographic assay.
Specimen: Secretions from cloaca or feces
Materials provided:
5 PR. TGA Ag test cards
5 Vials of assay buffer
5 Disposable droppers
5 Specimen collection swabs
1 Instruction for use
Special Features:
High sensitivity and Accuracy.
Relative Sensitivity: 96.50%
Relative Specificity: 97.06%
Relative Accuracy: 97.25%

 

Test Procedure

1. Remove the test card from the foil pouch and place it flat on a work surface.
2. Transfer 4 drops of the treated sample from the assay buffer tube into the sample well.
3. Start the timer. Wait for 5 to 10 minutes to read the result.

-Positive (+): Both the Control (C) line and Test (T) line appear as magenta-colored lines in the testing window. Any faintly visible T line -should be considered positive when the C line is also present.
-Negative(-): The C line is visible, but the T line is not visible.
-Invalid: No line appears in the C zone.

1. Turn on the FIC-Q100N Dry Immunoassay Analyzer.
2. Use the analyzer's scanner to scan the QR code on the inner label of the box or the label of bag to import the calibration curve into the analyzer.
3. Remove the test card from the foil pouch.
4. Position the front of the card facing up, ensuring that the sample well is oriented towards the outside of the analyzer's test card slot.
5. Insert the card into the test card slot of the analyzer.
6. Transfer 4 drops of the treated sample from the assay buffer tube into the sample well of the test card.
7. Push the test card to the farthest end of the slot.
8. Tap "Standard Test" on the screen to start the testing. Please refer to the analyzer's operation manual for detailed instructions.

 

Test procedures of instrumental interpretation (Quick Test)

1. Turn on the FIC-Q100N Dry Immunoassay Analyzer .
2. Use the analyzer's scanner to scan the QR code on the inner label of the box or the label of bag to import the calibration curve into the analyzer.
3. Remove the test card from the foil pouch.
4. Transfer 4 drops of the treated sample from the assay buffer tube into the sample well of the test card.
5. Wait for 5-10 minutes, then push the test card to the farthest end of the test card slot.
6. Tap "Quick Test" on the screen to start the testing. Please refer to the analyzer's operation manual for detailed instructions.

 

Order Information

Product No.Product NameStorage TemperaturePackage Unit
VD100QPet Reptile Trichomonas Antigen Test2-30°C10 Tests/Box

 

Click

 

เว็บไซต์นี้มีการใช้งานคุกกี้ เพื่อเพิ่มประสิทธิภาพและประสบการณ์ที่ดีในการใช้งานเว็บไซต์ของท่าน ท่านสามารถอ่านรายละเอียดเพิ่มเติมได้ที่ นโยบายความเป็นส่วนตัว และ นโยบายคุกกี้